{"id":2418,"date":"2026-07-01T11:58:10","date_gmt":"2026-07-01T03:58:10","guid":{"rendered":"https:\/\/www.fulerdiesel.com\/the-noise-reduction-of-generator-room\/"},"modified":"2026-07-01T11:58:10","modified_gmt":"2026-07-01T03:58:10","slug":"the-noise-reduction-of-generator-room","status":"publish","type":"post","link":"https:\/\/www.fulerdiesel.com\/vi\/the-noise-reduction-of-generator-room\/","title":{"rendered":"The noise reduction of generator room"},"content":{"rendered":"<p>The noise reduction of generator room<br \/>\nWhen diesel\u00a0generator\u00a0is running, usually produces 95 ~ 128 db (a) of the noise. If you do not take the necessary noise reduction measures, the unit will run the noise caused serious damage to the surrounding environment. To protect and improve the quality of the environment, you need control noise.<br \/>\nDiesel\u00a0generators\u00a0are the main noise sources produce diesel\u00a0engines, including exhaust noise, mechanical noise and combustion noise, cooling fan and exhaust noise, into the wind noise,\u00a0generator\u00a0noise, ground vibration generated by the transmission of noise:<br \/>\n1, the exhaust noise. Exhaust noise is a high temperature, high-speed pulse of air noise,\u00a0engine\u00a0noise is a maximum of energy, up to 100 db above the noise, the total\u00a0engine\u00a0noise is the most important part.\u00a0generator\u00a0exhaust noise generated when the work by the simple exhaust pipe (exhaust pipe\u00a0generator\u00a0first wife) direct discharge, and with the air speed increases, the noise frequency is also significantly improved, so that nearby residents living and working are not severely affected.<br \/>\n2, mechanical noise and combustion noise. Mechanical noise is mainly the\u00a0engine\u00a0moving parts during operation by the gas pressure and inertia forces caused by changes in the cycle of vibration or shock generated by each. It has spread far from the noise, reduce bad characteristics. Diesel combustion noise is generated in the combustion process structure vibration and noise.<br \/>\n3, the cooling fan and exhaust noise. Unit fan noise is the noise from the vortex, rotating noise and mechanical noise component. Exhaust noise, air noise, fan noise, mechanical noise will be spread out through the exhaust channel, thereby causing noise pollution on the environment.<br \/>\n4, into the wind noise. The role of the inlet channel is: to ensure the normal operation of the\u00a0engine\u00a0and the unit itself to create a good thermal conditions. Unit into the air inlet channel must be able to smoothly enter the room, but the unit of mechanical noise, the noise will air through the inlet channel of radiation to the room outside.<br \/>\n5, the transmission of ground vibration noise. Diesel strong mechanical vibrations can be transmitted long distances through the ground around the outside and then re-radiated noise floor.<br \/>\nDiesel\u00a0generator\u00a0room noise reduction principle is to ensure that the ventilation of diesel\u00a0generators\u00a0do not reduce the output power of the premise, the use of efficient sound-absorbing materials and noise muffler for Jin, ventilation channels and exhaust system for noise reduction, so that noise emissions to achieve the national standard (85db (a)).<br \/>\nNoise\u00a0generator\u00a0is the most fundamental way to proceed from a sound source, the use of some conventional noise reduction techniques; such as mufflers, sound insulation, sound absorption, vibration isolation, etc. are the most effective way.<br \/>\n1, reduce exhaust noise. Exhaust noise is the main noise source unit, which is characterized by high noise levels, exhaust speed, control is difficult. Impedance using a special type of compound muffler, exhaust noise will generally reduce the 40-60 db (a).<br \/>\n2, lower axial fan noise. Reduce the\u00a0generator\u00a0cooling fan noise, we must consider two questions, one exhaust channel pressure loss allowed. Second, muffler requirements. In response to these two points, the choice of the resistive film type muffler.<br \/>\n3, room acoustic, acoustic treatment and isolation unit<br \/>\n(1), room noise. Unit and cooling fan noise, exhaust noise reduction, the remaining major noise source is the diesel\u00a0engine\u00a0mechanical noise and combustion noise. Approach is necessary in addition to the observation room connected with the interior observation window, the other windows were removed, all holes, the hole to compact block, brick wall of sound insulation required to be 40 db (a) above.\u00a0Engine\u00a0room sound insulation, fire-resistant doors and windows doors and windows.<br \/>\n(2), inlet and exhaust. Room acoustic treatment, the\u00a0engine\u00a0room ventilation to solve the problem. Air inlet should be generating sets, air vents set in a straight line. Air inlet should be accompanied by a resistive film type muffler, air inlet pressure loss due also within the permissible range, the\u00a0engine\u00a0room can balance out the natural air flow, ventilation and heat dissipation effect is obvious.<br \/>\n(3), acoustic treatment. In addition to the\u00a0engine\u00a0room on the ground outside the wall can be used for five acoustic treatment, according to the spectral characteristics of\u00a0generators\u00a0using resonant acoustic perforated board structure.<br \/>\n(4), the exchange of indoor air, a good room sound insulation, water-cooled\u00a0generator\u00a0set will shut down time closed room without air convection, room temperature can not be down in time, can be low-noise axial fan , matched resistive film muffler can solve the problem.<br \/>\n(5), unit isolation.\u00a0Generator\u00a0installation, should be strictly according to the manufacturer for isolation provided information processing, to avoid long-distance propagation of acoustic and continue to spread radiation in the air sound, noise level can not make the plant community standards.Exceeded the requirements of governance due to the existing generating units, the unit must be measured near the ground vibration, if vibration sense was, the first isolation of generating units for processing.<br \/>\nReduction in the effective noise, in order to make the environment more beautiful and functional room, typically the walls and ceiling with sound-absorbing layer of porous aluminum punching things, decorative plates, while the rational allocation of lighting systems.<\/p>","protected":false},"excerpt":{"rendered":"<p>The noise reduction of generator room When diesel\u00a0generator\u00a0is running, usually produces 95 ~ 128 db (a) of the noise. If you do not take the necessary noise reduction measures, the unit will run the noise caused serious damage to the surrounding environment. To protect and improve the quality of the environment, you need control noise. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-2418","post","type-post","status-publish","format-standard","hentry","category-news"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>The noise reduction of generator room - Dalian Fuler Diesel Engine Co., Ltd.<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.fulerdiesel.com\/vi\/the-noise-reduction-of-generator-room\/\" \/>\n<meta property=\"og:locale\" content=\"vi_VN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"The noise reduction of generator room - Dalian Fuler Diesel Engine Co., Ltd.\" \/>\n<meta property=\"og:description\" content=\"The noise reduction of generator room When diesel\u00a0generator\u00a0is running, usually produces 95 ~ 128 db (a) of the noise. If you do not take the necessary noise reduction measures, the unit will run the noise caused serious damage to the surrounding environment. To protect and improve the quality of the environment, you need control noise. [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.fulerdiesel.com\/vi\/the-noise-reduction-of-generator-room\/\" \/>\n<meta property=\"og:site_name\" content=\"Dalian Fuler Diesel Engine Co., Ltd.\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-01T03:58:10+00:00\" \/>\n<meta name=\"author\" content=\"frances@fulerdiesel.com\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0110\u01b0\u1ee3c vi\u1ebft b\u1edfi\" \/>\n\t<meta name=\"twitter:data1\" content=\"frances@fulerdiesel.com\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u01af\u1edbc t\u00ednh th\u1eddi gian \u0111\u1ecdc\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 ph\u00fat\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.fulerdiesel.com\\\/the-noise-reduction-of-generator-room\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.fulerdiesel.com\\\/the-noise-reduction-of-generator-room\\\/\"},\"author\":{\"name\":\"frances@fulerdiesel.com\",\"@id\":\"https:\\\/\\\/www.fulerdiesel.com\\\/#\\\/schema\\\/person\\\/1d744bfa40ac9bff3385cc9c663cefc0\"},\"headline\":\"The noise reduction of generator room\",\"datePublished\":\"2026-07-01T03:58:10+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.fulerdiesel.com\\\/the-noise-reduction-of-generator-room\\\/\"},\"wordCount\":867,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.fulerdiesel.com\\\/#organization\"},\"articleSection\":[\"News\"],\"inLanguage\":\"vi\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.fulerdiesel.com\\\/the-noise-reduction-of-generator-room\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.fulerdiesel.com\\\/the-noise-reduction-of-generator-room\\\/\",\"url\":\"https:\\\/\\\/www.fulerdiesel.com\\\/the-noise-reduction-of-generator-room\\\/\",\"name\":\"The noise reduction of generator room - Dalian Fuler Diesel Engine Co., Ltd.\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.fulerdiesel.com\\\/#website\"},\"datePublished\":\"2026-07-01T03:58:10+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.fulerdiesel.com\\\/the-noise-reduction-of-generator-room\\\/#breadcrumb\"},\"inLanguage\":\"vi\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.fulerdiesel.com\\\/the-noise-reduction-of-generator-room\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.fulerdiesel.com\\\/the-noise-reduction-of-generator-room\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.fulerdiesel.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"The noise reduction of generator room\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.fulerdiesel.com\\\/#website\",\"url\":\"https:\\\/\\\/www.fulerdiesel.com\\\/\",\"name\":\"Dalian Fuler Diesel Engine Co., Ltd.\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.fulerdiesel.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.fulerdiesel.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"vi\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.fulerdiesel.com\\\/#organization\",\"name\":\"Dalian Fuler Diesel Engine Co., Ltd.\",\"url\":\"https:\\\/\\\/www.fulerdiesel.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"vi\",\"@id\":\"https:\\\/\\\/www.fulerdiesel.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.fulerdiesel.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/2026070116330060678dff.png\",\"contentUrl\":\"https:\\\/\\\/www.fulerdiesel.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/2026070116330060678dff.png\",\"width\":1311,\"height\":636,\"caption\":\"Dalian Fuler Diesel Engine Co., Ltd.\"},\"image\":{\"@id\":\"https:\\\/\\\/www.fulerdiesel.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.fulerdiesel.com\\\/#\\\/schema\\\/person\\\/1d744bfa40ac9bff3385cc9c663cefc0\",\"name\":\"frances@fulerdiesel.com\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"vi\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f2e7924edc1e6f7ced91048c6a55680353ab8d0ffd488c3877d7ddd2cdfa4e6a?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f2e7924edc1e6f7ced91048c6a55680353ab8d0ffd488c3877d7ddd2cdfa4e6a?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f2e7924edc1e6f7ced91048c6a55680353ab8d0ffd488c3877d7ddd2cdfa4e6a?s=96&d=mm&r=g\",\"caption\":\"frances@fulerdiesel.com\"},\"sameAs\":[\"https:\\\/\\\/www.fulerdiesel.com\"],\"url\":\"https:\\\/\\\/www.fulerdiesel.com\\\/vi\\\/author\\\/haozhutigmail-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"The noise reduction of generator room - Dalian Fuler Diesel Engine Co., Ltd.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.fulerdiesel.com\/vi\/the-noise-reduction-of-generator-room\/","og_locale":"vi_VN","og_type":"article","og_title":"The noise reduction of generator room - Dalian Fuler Diesel Engine Co., Ltd.","og_description":"The noise reduction of generator room When diesel\u00a0generator\u00a0is running, usually produces 95 ~ 128 db (a) of the noise. If you do not take the necessary noise reduction measures, the unit will run the noise caused serious damage to the surrounding environment. To protect and improve the quality of the environment, you need control noise. [&hellip;]","og_url":"https:\/\/www.fulerdiesel.com\/vi\/the-noise-reduction-of-generator-room\/","og_site_name":"Dalian Fuler Diesel Engine Co., Ltd.","article_published_time":"2026-07-01T03:58:10+00:00","author":"frances@fulerdiesel.com","twitter_card":"summary_large_image","twitter_misc":{"\u0110\u01b0\u1ee3c vi\u1ebft b\u1edfi":"frances@fulerdiesel.com","\u01af\u1edbc t\u00ednh th\u1eddi gian \u0111\u1ecdc":"4 ph\u00fat"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.fulerdiesel.com\/the-noise-reduction-of-generator-room\/#article","isPartOf":{"@id":"https:\/\/www.fulerdiesel.com\/the-noise-reduction-of-generator-room\/"},"author":{"name":"frances@fulerdiesel.com","@id":"https:\/\/www.fulerdiesel.com\/#\/schema\/person\/1d744bfa40ac9bff3385cc9c663cefc0"},"headline":"The noise reduction of generator room","datePublished":"2026-07-01T03:58:10+00:00","mainEntityOfPage":{"@id":"https:\/\/www.fulerdiesel.com\/the-noise-reduction-of-generator-room\/"},"wordCount":867,"commentCount":0,"publisher":{"@id":"https:\/\/www.fulerdiesel.com\/#organization"},"articleSection":["News"],"inLanguage":"vi","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.fulerdiesel.com\/the-noise-reduction-of-generator-room\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.fulerdiesel.com\/the-noise-reduction-of-generator-room\/","url":"https:\/\/www.fulerdiesel.com\/the-noise-reduction-of-generator-room\/","name":"The noise reduction of generator room - Dalian Fuler Diesel Engine Co., Ltd.","isPartOf":{"@id":"https:\/\/www.fulerdiesel.com\/#website"},"datePublished":"2026-07-01T03:58:10+00:00","breadcrumb":{"@id":"https:\/\/www.fulerdiesel.com\/the-noise-reduction-of-generator-room\/#breadcrumb"},"inLanguage":"vi","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.fulerdiesel.com\/the-noise-reduction-of-generator-room\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.fulerdiesel.com\/the-noise-reduction-of-generator-room\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.fulerdiesel.com\/"},{"@type":"ListItem","position":2,"name":"The noise reduction of generator room"}]},{"@type":"WebSite","@id":"https:\/\/www.fulerdiesel.com\/#website","url":"https:\/\/www.fulerdiesel.com\/","name":"C\u00f4ng ty TNHH \u0110\u1ed9ng c\u01a1 diesel Dalian Fuler.","description":"","publisher":{"@id":"https:\/\/www.fulerdiesel.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.fulerdiesel.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"vi"},{"@type":"Organization","@id":"https:\/\/www.fulerdiesel.com\/#organization","name":"C\u00f4ng ty TNHH \u0110\u1ed9ng c\u01a1 diesel Dalian Fuler.","url":"https:\/\/www.fulerdiesel.com\/","logo":{"@type":"ImageObject","inLanguage":"vi","@id":"https:\/\/www.fulerdiesel.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.fulerdiesel.com\/wp-content\/uploads\/2026\/05\/2026070116330060678dff.png","contentUrl":"https:\/\/www.fulerdiesel.com\/wp-content\/uploads\/2026\/05\/2026070116330060678dff.png","width":1311,"height":636,"caption":"Dalian Fuler Diesel Engine Co., Ltd."},"image":{"@id":"https:\/\/www.fulerdiesel.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.fulerdiesel.com\/#\/schema\/person\/1d744bfa40ac9bff3385cc9c663cefc0","name":"frances@fulerdiesel.com","image":{"@type":"ImageObject","inLanguage":"vi","@id":"https:\/\/secure.gravatar.com\/avatar\/f2e7924edc1e6f7ced91048c6a55680353ab8d0ffd488c3877d7ddd2cdfa4e6a?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/f2e7924edc1e6f7ced91048c6a55680353ab8d0ffd488c3877d7ddd2cdfa4e6a?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/f2e7924edc1e6f7ced91048c6a55680353ab8d0ffd488c3877d7ddd2cdfa4e6a?s=96&d=mm&r=g","caption":"frances@fulerdiesel.com"},"sameAs":["https:\/\/www.fulerdiesel.com"],"url":"https:\/\/www.fulerdiesel.com\/vi\/author\/haozhutigmail-com\/"}]}},"_links":{"self":[{"href":"https:\/\/www.fulerdiesel.com\/vi\/wp-json\/wp\/v2\/posts\/2418","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fulerdiesel.com\/vi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.fulerdiesel.com\/vi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.fulerdiesel.com\/vi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fulerdiesel.com\/vi\/wp-json\/wp\/v2\/comments?post=2418"}],"version-history":[{"count":0,"href":"https:\/\/www.fulerdiesel.com\/vi\/wp-json\/wp\/v2\/posts\/2418\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.fulerdiesel.com\/vi\/wp-json\/wp\/v2\/media?parent=2418"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.fulerdiesel.com\/vi\/wp-json\/wp\/v2\/categories?post=2418"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.fulerdiesel.com\/vi\/wp-json\/wp\/v2\/tags?post=2418"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}